1ST-TSB200-07312024
Service Bulletin/Repair Instructions
Certain model year 2023-2025 Atlas E1, Interstate 24 E1 & Interstate 19 E1 touring coaches, the Volta System may fail to re-engage in the charging process, which could lead to the battery pack completely discharging.
1ST-TSB196-93023
Service Bulletin/Repair Instructions
Atlas E1 touring coaches equipped with the Volta Power System had the 30 Amp shore breakers installed in the incorrect position inside the breaker box. The 30 amp shore breakers are required to have a hold down bracket per the âNational Electrical Code â Article 551-RV 550.40(A), General Requirements, paragraph 408.36(F)â.