SIL-3143
Service Bulletin/Repair Instructions
Altec has learned that a 12-volt Airtronics relay installed in the PDM could have been manufactured to an insufficient threshold on certain units built from December 2004 to October 2022. This can cause the relay to overheat and fail, causing the accessory lights to stop working.
SIL 727
Service Bulletin/Repair Instructions
SIL 727 notified unit owners that Altec has discovered that a placard was installed on some cranes which has the incorrect torque for bolts used to attach the rotation bearing. This placard has torque values that do not agree with the values in the maintenance manual. This difference can cause rotation bearing fasteners to be insufficiently checked during the periodic torque inspections, possibly leading to accelerated bolt fatigue. Altec requires that the affected units be inspected for the correct rotation fastener torque placard.