CSR-3305
Service Bulletin/Repair Instructions
Altec Industries, Inc. has received notification from Ford that certain 2015-2019 model-year Ford vehicles equipped with Altec equipment require a one-time inspection of the rear-view camera to ensure that replacement is not required to prevent a condition that exists relating to motor vehicle safety and compliance.
CSR-3276
Service Bulletin/Repair Instructions
Altec Industries, Inc. has been notified by Ford Motor Company that a defect which relates to motor vehicle safety exists in certain 2015 - 2019 Model Year Ford vehicles. On the affected vehicles, the rear-view camera could display a blank or distorted image on the center display screen when the vehicle is in reverse. This relates to the operation and customer satisfaction of certain Altec units with service bodies.
SIL 850
Service Bulletin/Repair Instructions
The body compartment wiring on certain Altec aerial devices, digger derricks, and body-only units built from 2014 to 2021 contains an in-line fuse located close to the lighting in the compartment, while other units are fused upstream, closer to the power source. Altec has learned that the units affected should have an in-line fuse close to the lighting, but this fuse was not installed on some units. In addition, some units may have exposed terminals at the end of certain portions of the wiring in the body. If the exposed terminals contact each other or with ground, the resulting direct short could damage the body compartment lighting. Inspect the body compartment lighting circuit at the unit's next scheduled service interval or within six months of receiving the SIL, whichever comes first. Use the Inspection Procedure or contact Altec to perform the inspection. This inspection and repair are covered under the Altec Warranty Policy and can be performed by Altec, the customer, or the customer's warranty provider. Altec will perform the work for free at an Altec facility. If the customer or the customer's warranty provider performs the work, a warranty claim must be submitted to be reimbursed for the cost of the parts and/or labor.
SIL 790
Service Bulletin/Repair Instructions
It has been discovered that some hydraulic lines installed by Altec may be in contact with chassis air brake line(s). Some DOT inspections have considered this to be a violation of federal regulation 49 CFR § 393.45 b 2. Over time, chafing of the air brake line(s) could result in loss of air pressure and reduction in braking performance. Altec requires the routing of the hydraulic lines to be inspected no later than the next periodic maintenance interval. The affected unit are some T40P cable placers installed on Ford F750 chassis from May 2015 to January 2020
SIL 786
Service Bulletin/Repair Instructions
Some aluminum body doors and box lids require excessive force and may make a popping sound when being opened and closed. Certain bodies are equipped with doors or box lids that contain aluminum hinge rods going through metal hinges that are manufactured from a different metal. Under some conditions the hinges can stick or seize due to salt solutions that damage the protective coating of the aluminum hinge rod. If the hinge rod seizes, it can cause damage to the hinge, door, or box lid. To protect the hinge rod from being damaged and seizing, clean the hinge rod and apply a corrosion inhibitor lubricant. A checklist and lubrication process is provided with the notification to include in the Preventive Maintenance and Inspection Checklist for future use.