Vehicle report

2019 ARBOC SPIRIT OF MOBILITY

Service bulletins

1 bulletin

Technical service bulletins are instructions a manufacturer sent its dealers about a known fault. They are not recalls and the work is usually not free, but they are the clearest signal of a problem the manufacturer already knows about.

AR888

Service Bulletin/Repair Instructions

Step 1: Add 5/16" ring terminal to Viair compressor power wires. See Figure 1. Install ring terminal, Typ. Both compressors. Loom wires together. Step 2: Drill mounting holes in compressor box tray. Follow instructions on paper template to drill holes in compressor box tray. Step 3: Install isolators on tray. Discard isolators that come with Viair compressor. Use isolator #2002833 (Figure 2) to mount Viair compressors to box tray (8-PLCS). Step 4: Install air filters on compressors. Discard plastic ring on air filters. Use Teflon tape on threads. Install filters on compressors (Figure 3). Step 5: P-Clamp Securement. Through bolt 7/8" P-clamps (qty 2) to box tray to secure "T" fitting (Figure 4). Step 6: Power wires. Wire Viair compressors identical to the Thomas compressor wiring.

Reading this report

Complaint counts are reports filed with NHTSA, not failure rates. A common model collects more of them than a rare one that breaks more often.