Vehicle report

2022 DEMERS MXP153E

Safety recalls

2 campaigns

23V117000

STRUCTURE:BODY:STEP/LADDER Recall

Braun Ambulances (Braun) is recalling certain 2022 Demers ambulances, models MX164E, MX170E, MXP150E, MXP150Z, MXP153E, MXP170MLE, MXP170Z, and 2020, 2022 MXP170E. The rear step of the ambulance may fail under weight due to incorrect welding.

Remedy: Braun will send a reinforcement plate to be installed on the rear step, free of charge. Owner notification letters were mailed April 11, 2023. Owners may contact Braun customer service at 1-877-344-9990.

22V915000

STRUCTURE:BODY Recall

Braun Ambulances (Braun) is recalling certain 2022 Demers MXP153E ambulances. The rear battery compartment may be missing the ventilation hole.

Remedy: Owners are advised not to drive their ambulances until the remedy has been completed. Dealers will drill a hole and install a filter in the rear battery compartment, free of charge. Owner notification letters were mailed January 12, 2023. Owners may contact Braun's customer service at 1-877-344-9990.

Reading this report

Complaint counts are reports filed with NHTSA, not failure rates. A common model collects more of them than a rare one that breaks more often.