Technical service bulletins are instructions a manufacturer sent its dealers about a known fault. They are not recalls and the work is usually not free, but they are the clearest signal of a problem the manufacturer already knows about.
DOR-T7F8K-08
Service Bulletin/Repair Instructions
These SKUs are Trailer Brake Control Modules. The customer communication requested return of unsold inventory due to an internal software issue. The internal software issue leads to a false check trailer brake message and Trailer Brake Controller fault whenever the brake pedal is pressed. This will cause the part to be replaced, due to repetitive dashboard warning light, even though it sends signals to the trailer brakes properly.
ASI-44534
Service Bulletin/Repair Instructions
FORD: WHEN SHIFTING BETWEEN PARK, REVERSE AND/OR DURING 2-3 SHIFT, AN INTERMITTENT CLUNK OCCURS WITH A TORQSHIFT TRANSMISSION. MODEL 2003-2014 F-SUPER DUTY, E SERIES, EXCURSION, F-53 MOTORHOME CHASSIS, LOW CAB FORWARD. *PE
ASI-44404
Service Bulletin/Repair Instructions
FORD: ON SOME TRUCKS, THERE IS A NO CRANK SITUATION AND IF VOLTAGE ON TRANSMISSION RANGE SENSOR AT PIN 21, IS LESS THAN 5 VOLTS, DISCONNECT THE ENGINE COOLING FAN CLUTCH, ELECTRONICALLY, AND RECHECK VOLTAGE. MODEL 2003-2007 F SUPER DUTY, 2004-2010 E SERIES, 2003-2005 EXCURSION.
AS-21769
Service Bulletin/Repair Instructions
FORD: IF THERE IS AN INTERMITTENT LACK OF POWER, SURGE, OR HESITATION WHILE DRIVING THE BRAKES WILL OVERRIDE ACCELERATION. *RM
TSB-08-26-3
Service Bulletin/Repair Instructions
FORD: SOME VEHICLES WITH DIESEL ENGINES MAY EXPERIENCE NO STARTS, HARD STARTS OR ROUGH RUNNING WHEN COLD AND MAY BE ACCOMPANIED WITH DIAGNOSTIC TROUBLE CODES (DTCS) P0611, P1378 AND/OR ALL 8 INJECTOR CIRCUIT CODES. *PE
TSB-08-20-1
Service Bulletin/Repair Instructions
FORD TRUCKS: MISFIRE, LACK OF POWER, BUCK/JERK, EXCESSIVE SMOKE, CRANK/NO START-DIAGNOSTICS FOR FUEL SYSTEM. THERE ARE SEVERAL POTENTIAL CAUSES FOR THESE SYMPTOMS. *PE
TSB T2007-02
Service Bulletin/Repair Instructions
ON SOME VEHICLES, WHEN THE GATEWAY 401 MODULE TRANSITIONS FROM ITS POWER DOWN MODE (IGNITION OFF) TO ITS POWER UP MODE (IGNITION ON) THE MODULE MAY NOT WAKE UP. IF THIS ACTION OCCURS, THE MODULE'S LED DISPLAY PANELS WILL NOT PROVE-OUT AND THE BACKLIGHTS ON THE LED DISPLAY PANELS WILL NOT ILLUMINATE.