Vehicle report

2016 MCNEILUS ATLANTIC FRONT LOADER

Service bulletins

12 bulletins

Technical service bulletins are instructions a manufacturer sent its dealers about a known fault. They are not recalls and the work is usually not free, but they are the clearest signal of a problem the manufacturer already knows about.

MISC-IB-084-A

Service Bulletin/Repair Instructions

McNeilus Truck and Manufacturing requires an inspection and replacement, if needed, to ensure the Bob Tail® Huck® bolts are fully swaged with correct thread exposure on the rear pivot cross member body mounts. Revision A updates the replacement bolt length to 90mm

MISC-IB-084

Service Bulletin/Repair Instructions

McNeilus Truck and Manufacturing requires an inspection and replacement, if needed, to ensure the Bob Tail® Huck® bolts are fully swaged with correct thread exposure on the rear pivot cross member body mounts.

MISC-TSIB-081

Service Bulletin/Repair Instructions

According to an amended ruling in the visual inspection labeling requirement in Federal Motor Vehicle Safety Standard (FMVSS) No. 304, the periodic inspection interval for compressed natural gas (CNG) fuel containers has been modified to “at least every 12 months.” McNeilus Truck and Manufacturing will support this change by updating safety decals and installing these new decals when a vehicle is inspected by McNeilus CNG technicians, and by answering questions regarding this periodic inspection interval update and how McNeilus will support it.

MISC-TSIB-079

Service Bulletin/Repair Instructions

McNeilus Truck and Manufacturing provides these instructions for installing a hydraulic reservoir cork gasket. The installation of this gasket will repair leaks coming from the gasket between the in-tank filter and the reservoir.

MISC-TSIB-075-A

Service Bulletin/Repair Instructions

The following information describes how to purge air and release stored hydraulic energy from a hydraulic system. All manual override features are intended for emergency use, not for continuous-duty operation.

FEL-WI-018-A

Service Bulletin/Repair Instructions

McNeilus Truck and Manufacturing offers these instructions for repairing the lugs on the Front Loader Meridian and Front Loader Atlantic CNG tailgates.

MISC-TSIB-078

Service Bulletin/Repair Instructions

McNeilus Truck and Manufacturing offers these instructions for ejector cylinder bypass testing.

VSR-WI-003-A

Service Bulletin/Repair Instructions

Internal Document work instructions. McNeilus Truck and Manufacturing, Inc. has been alerted by our supplier that a concern affecting safety exists in some Emcara Pressure Relief Device (PRD) valves on CNG tanks (for your information,Emcara?s NHTSA Recall number is 15E059). Some McNeilus Refuse models were shipped with an Emcara CNG PRD which may not vent properly. The purpose of the thermal PRD is to relieve pressure in the CNG system if the CNG tank is reaching an unsafe level of pressure, as might occur with a thermal event that heats up a tank. In the event of a thermal event, the thermal PRD may not vent properly, which increases the likelihood of a CNG tank over-pressurizing and rupturing. A tank rupture creates an increased risk of injury to the truck occupants, firefighters, or bystanders.

VSR-WI-004-A

Service Bulletin/Repair Instructions

Internal Document work instructions. McNeilus Truck and Manufacturing, Inc. has been alerted by our supplier that a concern affecting safety exists in some Emcara Pressure Relief Device (PRD) valves on CNG tanks (for your information,Emcara?s NHTSA Recall number is 15E059). Some McNeilus Refuse models were shipped with an Emcara CNG PRD which may not vent properly. The purpose of the thermal PRD is to relieve pressure in the CNG system if the CNG tank is reaching an unsafe level of pressure, as might occur with a thermal event that heats up a tank. In the event of a thermal event, the thermal PRD may not vent properly, which increases the likelihood of a CNG tank over-pressurizing and rupturing. A tank rupture creates an increased risk of injury to the truck occupants, firefighters, or bystanders.

MISC-TSIB-072 -

Service Bulletin/Repair Instructions

This technical service information bulletin describes the replacement of a snapper pin with a bolted joint in the body service lift pin assembly. The body service lift is used to raise the refuse collection body during maintenance operations. The snapper pins are adequate for retaining the body service lift pins, however the new method being used in production is a bolt and nut connection.

FEL-TSIB-048 - A

Service Bulletin/Repair Instructions

This technical service information bulletin describes the replacement of a refuse deflector with a cover system that provides enhanced refuse deflection. The refuse deflector system is designed to sweep refuse off of the hopper cover and into the body in the event refuse spills onto the hopper cover. The enhanced refuse deflector is designed to reduce the hopper cover cleaning requirements.

FEL-TSIB-049 - A

Service Bulletin/Repair Instructions

This technical service information bulletin describes the replacement of a refuse deflector with a cover system that provides enhanced refuse deflection. The refuse deflector system is designed to sweep refuse off of the hopper cover and into the body in the event refuse spills onto the hopper cover. The enhanced refuse deflector is designed to reduce the hopper cover cleaning requirements.

Reading this report

Complaint counts are reports filed with NHTSA, not failure rates. A common model collects more of them than a rare one that breaks more often.

2016 Mcneilus Atlantic Front Loader Service Bulletins: 12 bulletins | CarFathom