251030 Battery email
Other
A consumer notification indicating one of New Flyer's battery suppliers is exiting the market.
Vehicle report
Technical service bulletins are instructions a manufacturer sent its dealers about a known fault. They are not recalls and the work is usually not free, but they are the clearest signal of a problem the manufacturer already knows about.
251030 Battery email
A consumer notification indicating one of New Flyer's battery suppliers is exiting the market.
TSIB 25-07
This Bulletin is being issued due to New Flyer & MCI have received reports that customers are re-torquing high-voltage (HV) connections during preventative maintenance inspections as outlined in the Preventive Maintenance section of the Service or Maintenance manual. This Bulletin reminds operators that the inspection procedure is visual only and does not require retorque unless the witness marks indicate the fasteners have loosened.
TSIB 25-04
This Technical Service Information Bulletin has been issued to remind customers that fill pressure must not exceed 25 psi to avoid injury or damage components during filling and deaeration of the ESS Battery Thermal Management System.
IST-60523
ITS was issued to correct the orientation of HV contactors. Incorrect orientation can lead to premature failure
TSIB 22-08
New Flyer has issued Technical Service Information Bulletin (TSIB) 22-08, providing for the application of silicone paste onto overhead charging rails to inhibit water from collecting on the rails
ITS60372
This Instruction to Service describes how to remove and replace the circuit breakers for a Valeo coolant pump installed on specifically equipped buses.
ITS58926
Technical Instruction describing the DC charge rail and COM box lid replacement and inspection requirement
190524-115466
Programmable Logic Controller (PLC) program change - to correct the requirement to manually cycle the rear doors open and closed before operating the bus.
200508-116387
Programmable Logic Controller (PLC) program change - to resolve several issues and incorporate several improvements related to the XALT battery systems installed on specific on Battery Electric buses.
ITS58912
Technical Instruction describing the DC charge rail box power cable replacement.
ITS58874
Technical Instruction describing the inspection procedures for the high voltage systems on a battery electric bus.
SMB189
Service Manual Bulletin - Update to high voltage safety procedures, specifically Lockout/Tagout, de-energizing and re-energizing procedures for both battery electric and fuel cell buses.
SMB186
Service Manual Bulletin providing revised, corrected or additional information for the Preventive Maintenance on buses specifically equipped with a Powerex direct drive air compressor.
SMB188
Service Manual Bulletin provides revised information for the Preventive Maintenance on specifically equipped vehicles with the Powerex belt driven air compressor.
SMB187
Service Manual Bulletin which stresses the need for safety when performing maintenance on the high voltage systems on your New Flyer vehicle.
SMB185
Service Manual Bulletin describing a modification to the lubrication procedure for the Energy Storage System (ESS) battery coolant filter replacement, during normal preventative maintenance schedule.
ITS58621
Instruction to Service - retrofit instructions for modification to air compressor snorkel air intake
SMB183
This Service Manual and Operators Guide Bulletin Adds a WARNING Regarding Safe Operation of Roof-top Escape Hatches, While Charging a Battery Electric Vehicle.
ITS6786
This Maintenance Instruction Decribes How to Replace Electric Motor Mounting Bolts.
PMB049
This Parts Manual Bulletin provides new part number information for the moveable arm kit for the Kongsberg brake and accelerator assembly on specifically equipped vehicles.
SMB178
This Service Manual Bulletin provides new OEM (Kongsberg) PM inspection requirements and new installation procedure for the adjustable floor pedal moveable arm on specifically equipped vehicles.
SMB176
This Service Manual Bulletin provides new information on how to check for proper chain tension, as measured by the chain deflection, while performing the ramp mechanism initial adjustments. This bulletin only applies to vehicles with New Flyer designed ramps.
SMB173
This bulletin provides PM inspection requirements for the K-menber on the fuel tank support structure
ITS5909
NEW FLYER: 2010 EPA OR NEWER ENGINES AND MINI-HYBRID COOLING SYSTEM BUSES WITH ISOLATED PIPE CLAMPS MAY EXPERIENCE RADIATOR CORROSION. *TA
Complaint counts are reports filed with NHTSA, not failure rates. A common model collects more of them than a rare one that breaks more often.