Vehicle report

2018 QUANTUM FUEL SYSTEMS LLC. VP LITE

Service bulletins

16 bulletins

Technical service bulletins are instructions a manufacturer sent its dealers about a known fault. They are not recalls and the work is usually not free, but they are the clearest signal of a problem the manufacturer already knows about.

TSB-050

Service Bulletin/Repair Instructions

An additional cross member or front sill is welded behind the header panel in PRATT chassis, this front sill is designed to support the front of the VP container. The front sill is supposed to be flush with the top of the frame rails. In some cases this front sill has been found to be too low which can result in damage and wear of the VP container.

TSB-049

Service Bulletin/Repair Instructions

In severe operating conditions, some sleeves on the bottom of the cylinders positioned over the tractor tires may experience accelerated wear. The sleeve that the lower flex plate is secured to can become worn to the point that it fails and no longer restrains the bottom of the cylinder.

TSB-048

Service Bulletin/Repair Instructions

Variation in the PRD bracket mounting hole location in the cross member may result in the PRD assembly installation height being too high resulting in contact between the roof panel and PRD inlet pipe. A revised bracket allows adjustment of the installed height of the PRD assembly.

TSB-040

Service Bulletin/Repair Instructions

A new fastening method has been developed to improve the connection between the chassis and the container. In the event of a roll over collision this new fastening method should be more durable than the original chassis pin.

TSB-036

Service Bulletin/Repair Instructions

Some Quantum VP trailers have been found to have the PRD trigger tube support block coming loose from the cylinder.

TSB-038

Service Bulletin/Repair Instructions

Some Quantum VP trailers mounted on Pratt chassis have been found to have a chafe concern between the chassis wiring and the chassis insert that was added as directed by TSB-031. The air brake supply lines may also be exposed to possible chafe damage and should also be inspected.

TSB-037

Service Bulletin/Repair Instructions

The manual shut off valves used on the Quantum VP trailers may over time become loose. During trailer use, the manual shut off valves may not remain in the position selected by the operator. A new handle has been developed with a detent feature to lock the valve in the open position.

2742-001

Service Bulletin/Repair Instructions

Circle Seal Controls - Safety Recall Withdrawal

TSB-012

Service Bulletin/Repair Instructions

Frame Mount Cylinder Isolator Replacement

TSB-010

Service Bulletin/Repair Instructions

OMB Automatic Valve Plunger Failure

TSB-008

Service Bulletin/Repair Instructions

Frame Moiunt End Caps

SI-002

Service Bulletin/Repair Instructions

Cylinder Inspection Intervals

TSB-011

Service Bulletin/Repair Instructions

ITT Regulator PRD Discharge

SI-003

Service Bulletin/Repair Instructions

Insulation Kit Instructions

CAM-001

Service Bulletin/Repair Instructions

Circle Seal PRD Campaign 14E-013 - Select Circle Seal Pressure Relief Devices sold by Quantum, Product Safety Recall

TSB-009

Service Bulletin/Repair Instructions

High Voltage Safety Disconnect

Reading this report