MCD-009
Other
Stopped using the lights we had been using due to expense. Replaced with these, but these new lights have to be wired in instead of just clicking in. These are the instructions to wire in.
Vehicle report
Technical service bulletins are instructions a manufacturer sent its dealers about a known fault. They are not recalls and the work is usually not free, but they are the clearest signal of a problem the manufacturer already knows about.
MCD-009
Stopped using the lights we had been using due to expense. Replaced with these, but these new lights have to be wired in instead of just clicking in. These are the instructions to wire in.
Letter to dealer
This was a letter to our dealers we sent out when we first heard of the Kidde fire extinguisher recall, even though it was still unofficial. We knew our coaches on the dealers' lots contained Kidde and could not be sold unreplaced.
SB-36
TIFFIN MOTORHOMES: TSB CONTAINS NOTIFICATION OF OWNER LETTER. SELECT DOCUMENT SEARCH BUTTON BELOW. TWO SCREWS WAS NOT INSTALLED ON THE AIR CONDITION UNITS ON THE ROOF. *TA UPDATED 11/24/15. *PE
16AWG
RV: INSTRUCTIONS ON HOW TO INSTALL THE CHARGE SOLENOID WIRING IN A RV OR VEHICLE. *TA
C85-C86AC
TIFFIN MOTORHOMES: TSB CONTAINS NOTIFICATION OF OWNER LETTER. SELECT DOCUMENT SEARCH BUTTON BELOW. ALL TIFFIN MOTORHOMES WILL BE INSTALLING 2 BACK SCREWS OF THE C85 AND C86 A/C'S TO THE ROOF OF ALL TIFFIN MOTORHOMES. *TA.
WI-269
TIFFIN MOTORHOMES: EXHAUST TIP AND PIPES TO THE MUFFLER ON PHAETON MODELS NEEDS TO BE INSTALLED. *TA
WI-196
TIFFIN MOTORHOMES: TSB CONTAINS NOTIFICATION OF OWNER LETTER. SELECT DOCUMENT SEARCH BUTTON BELOW. SOME TIFFIN MOTORHOMES NEED DRIVER/PASSENGER SEATBELTS TIGHTENED ON THE MOUNTING BRACKETS LOCATED ON THE DRIVER/PASSENGER SIDEWALL. *TA
TC-2011-296
TIFFIN MOTORHOMES: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. FORMERLY SB-34. INFORMATION PERTAINING TO CERTAIN MOTORHOMES IN REGARDS TO THE EXHAUST SHIELD (POWERGLIDE) WHICH IS MOUNTED TOO CLOSE TO UNDERSIDE OF FLOOR. *PE
WI-0189
TIFFIN MOTORHOMES: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. INFORMATION IS BEING PROVIDED TO HELP PREVENT WATER FROM ENTERING THE UNIT AND COMING INTO CONTACT WITH WOODEN FLOOR BY USING SEALING UNDERNEATH BLACK PLASTIC CORNER COVERS AND FLAT FLOOR SLIDE OUT BOX. *PE
RC-11V-416
TIFFIN MOTORHOMES: THE INSULATION CAN MELT AND POSSIBLE CAUSE A FIRE DUE TO EXHAUST PIPE BEING MOUNT TOO CLOSE TO UNDERSIDE OF FLOOR. *PE
SB-34
TIFFIN MOTORHOME: SEE DOCUMENTS RELATED TO RECALL 11V-416 FOR OWNER LETTER. THE INSULATION CAN MELT DUE TO EXHAUST PIPE BEING MOUNTED TO CLOSE TO UNDERSIDE OF FLOOR. THIS COULD RESULT IN A POSSIBLE FIRE. *PE
WI-0188
TIFFIN MOTORHOMES: INFORMATION PROVIDED REGARDING THE HEAT SHIELD AND HEAT SOCK BEING ADDED TO POWERGLIDE 40QTH PHEATON. NO MODEL YEARS PROVIDED. *PE
Complaint counts are reports filed with NHTSA, not failure rates. A common model collects more of them than a rare one that breaks more often.