25V061000
STRUCTURE:BODY:STEP/LADDER Recall
Grand Design RV, LLC (Grand Design) is recalling certain 2019-2024 Grand Design Solitude fifth wheel trailers. The step tread joints may be unsupported, causing the tread to break.
Remedy: Dealers will reinforce the current step tread with a metal bracket, free of charge. Owner notification letters were mailed May 22, 2025. Owners may contact Grand Design customer service at 1-574-825-9679. Grand Design's number for this recall is 910048.
23V490000
SUSPENSION:REAR:SPRINGS:LEAF SPRING ASSEMBLY:U-BOLT, LEAF SPRING TO AXLE Recall
Grand Design RV, LLC. (Grand Design) is recalling certain 2021-2024 Momentum and Solitude fifth wheels, equipped with certain CURT 7000 and 8000 lb axles. The U-bolts may have been improperly tightened, which can cause the axle to move out of position.
Remedy: Dealers will inspect and tighten the U-bolts, as necessary. Any damaged components will be replaced. Repairs will be performed free of charge. Owner notification letters were mailed August 16, 2023. Owners may contact Grand Design customer service at 1-574-825-9679. Grand Design's number for this recall is 910039.
22V038000
EQUIPMENT:APPLIANCE:REFRIGERATOR Recall
Grand Design RV, LLC (Grand Design) is recalling certain 2013-2021 Momentum, Solitude, and Reflection recreational vehicles. A 110-volt wire in the refrigerator cabinet may be improperly secured, which could result in the wire contacting the refrigerator cooling unit, causing an electrical arc.
Remedy: Dealers will inspect and replace any damaged wiring, and properly secure the wires, free of charge. Owner notification letters were mailed on February 21, 2022. Owners may contact Grand Design customer service at 1-574-825-9679. Grand Design's number for this recall is 910026.
20V523000
EQUIPMENT:APPLIANCE:REFRIGERATOR Recall
Grand Design RV, LLC (Grand Design) is recalling certain 2017-2021 Solitude recreational trailers. The liquid propane (LP) supply line that runs through the exterior lower refrigerator compartment may contact the burner tube of the refrigerator, possibly damaging the line and causing an LP gas leak.
Remedy: Grand Design will notify owners, and dealers will inspect the LP supply line for damage, replacing it as necessary. All lines in the vicinity of the burner tube will be wrapped in a thermal foil heat barrier material, then secured away from the burner tube of the refrigerator with additional P-clamps, free of charge. The recall began September 17, 2020. Owners may contact Grand Design customer service at 1-574-825-9679. Grand Design's number for this recall is 910021.